Webhook Output

ESPGeiger can send radiation data to a custom URL endpoint via HTTP POST. This allows you to integrate your Geiger counter readings with your own services, databases or automation systems.

Setup

  1. Configure ESPGeiger: On the Config page, open the Upload tab, tick Enable under Webhook and enter your target URL in the Webhook section. Optionally set a Key for authenticating requests from your device.
  2. Set the interval: the submission interval in seconds, 10 to 3600. The default is 60 seconds.

ESPGeiger will report the Webhook submission status in the Web Interface console.

Your endpoint should reply with a body that contains OK. Anything else, including an empty 204 reply, is logged as Webhook: Error and /outputs shows the webhook as not OK, even though the data arrived.

Note: Only HTTP endpoints are supported. An HTTPS URL saves but is never sent (the console shows Webhook: URL not usable (http only)); it is never sent as plain HTTP.

The URL must start with http:// and may carry a query string, for example http://192.168.1.10/hook?src=geiger&n=1. Characters outside the usual URL set, such as a space, ', #, [ or ], are refused when you save.

JSON Payload

ESPGeiger submits a JSON payload via HTTP POST with Content-Type: application/json. The following fields are included:

Field Type Description
id string Device chip ID
key string Configured webhook key (only included if set)
ut integer Uptime in seconds
cpm float Current CPM (1-minute smoothed)
cpm5 float 5-minute smoothed CPM
cpm15 float 15-minute smoothed CPM
usv float Current microsieverts per hour (µSv/h)
cps float Current counts per second
tc integer Total accumulated click count since boot
mem integer Free heap memory in bytes
rssi integer WiFi signal strength in dBm
tube integer 1 while counts are arriving, 0 once the tube has been silent longer than expected
sat integer 1 when the count rate is close to the tube’s dead-time limit
warn integer 1 when CPM is above the warning threshold
alert integer 1 when CPM is above the alert threshold
hv integer High voltage reading in volts (builds with HV feedback: ESPGeiger-HW, *_hv)
hv_fault integer 1 while HV is held off: over the voltage limit (same builds)
t float Temperature in °C (environment sensor only)
h float Relative humidity in % (BME280 / AHT family only)
p float Atmospheric pressure in hPa (BME280 / BMP280 only)

Environmental fields are emitted only when the corresponding sensor channel is available. A BMP280 ships t and p but not h; an AHT20 ships t and h but not p; a BME280 or AHT20+BMP280 combo ships all three.

Example JSON Output

{"id":"7a9256","ut":3600,"cpm":30.00,"cpm5":29.50,"cpm15":30.10,"usv":0.1987,"cps":0.50,"tc":1800,"mem":19088,"rssi":-45,"tube":1,"sat":0,"warn":0,"alert":0}